{"id":110517,"date":"2026-02-24T10:17:22","date_gmt":"2026-02-24T08:17:22","guid":{"rendered":"https:\/\/doktorvolt.pl\/sklep\/uncategorized\/ogranicznik-przepiec-ochronnik-4p-20-50ka-ac-t1-t2-doktorvolt-5064\/"},"modified":"2026-08-04T11:51:03","modified_gmt":"2026-08-04T09:51:03","slug":"ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064","status":"publish","type":"product","link":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/","title":{"rendered":"4P 20\u201350 kA AC T1\/T2 surge arrester, Doktorvolt DV-5064"},"content":{"rendered":"<h1 style=\"text-align:center;\"><span style=\"color:#000000;\">320 V AC surge arrester<\/span><br \/><span style=\"color:#000000;\">4P 20\u201350 kA, Class T1 and T2<\/span><\/h1>\n<\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:center;\"><span style=\"color:#000000;\">&#x2b50;&#x2b50;&#x2b50;&#x2b50;&#x2b50;<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x27a1;&#xfe0f; A surge arrester is a device that protects against transient overvoltages by limiting the frequency and duration of the follow-current. These devices are also known as lightning arresters, surge protectors or varistors. Surge arresters protect equipment connected to the mains and are also an essential component in the protection of solar installations.<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x27a1;&#xfe0f; T1\/T2 (\u2018combined\u2019) surge arresters are used to divert high-power surge currents with a 10\/350 \u03bcs waveform, which occur as a result of lightning strikes in three-phase and single-phase power supply networks (overhead lines) and\/or surges caused by overloads resulting from circuit switching (with an 8\/20 \u03bcs waveform). They are designed as compact units. Surge arresters comprising Type 1 and Type 2 (T1\/T2) protection units must be installed downstream of the first short-circuit protection device, immediately after the electricity meter (in the main switchboard).<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:center;\"><span style=\"color:#000000;\">&#x2b50;&#x2b50;&#x2b50;&#x2b50;&#x2b50;<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\"><strong>Features of the DV-5064 surge arrester:<\/strong><\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; Protection of electrical installation equipment against the effects of overvoltages<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; Protection of photovoltaic systems and connected equipment<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; T1\/T2 surge arrester type (class B+C)<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; DIN rail mounting (TH\/TS 35)<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; Complies with standard IEC (EN) 61643-11<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; Maximum cross-section of connected cable:<sup>35 mm\u00b2<\/sup><\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; 4-module<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; Rated voltage 320 V AC (alternating current)<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; Required fuse rating: 32 A<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; Voltage protection level up to 1.8 kV<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; Surge current Iimp: 7 kA<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\"><span style=\"color:#000000;\">&#x2714;&#xfe0f; The surge arresters are fitted with additional caps to cover the mounting holes<\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:justify;\">\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:center;\"><span style=\"color:#000000;\"><strong>&#x2757; The selection and installation of surge arresters must only be carried out by authorised, qualified personnel and depend on the type of lightning protection system used as well as the type of network. &#x2757;<\/strong><\/span><\/p>\n<p style=\"font-family:verdana, geneva;font-size:12pt;text-align:center;\">\n<table class=\"center\" style=\"background-color:#f5f5f5;margin-left:auto;margin-right:auto;width:627px;height:1357px;border:1px solid #ffffff;\" align=\"center\">\n<tbody>\n<tr align=\"left\">\n<td class=\"align_justify\" style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Application<\/span><span style=\"font-family:verdana, geneva;\"><br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\">\n<p><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">For the protection of electrical equipment in photovoltaic installations against the effects of surges<br \/>For the protection of TN and TT installations against induced voltages, switching voltages and voltages caused by atmospheric factors<br \/><span style=\"font-family:verdana, geneva;font-size:12pt;\"><\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr align=\"left\">\n<td class=\"align_justify\" style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Operating indicator<\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\">\n<p><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">green \u2013 protection <\/span><\/p>\n<p><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">red \u2013 no protection<\/span><\/p>\n<\/td>\n<\/tr>\n<tr align=\"left\">\n<td class=\"align_justify\" style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Protection class<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">T1 T2<br \/><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">number of modules<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;color:#000000;\"><span style=\"font-size:16px;\">4<\/span><\/span><\/td>\n<\/tr>\n<tr align=\"left\">\n<td class=\"align_justify\" style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Compliance with class requirements<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">T1 T2<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">maximum operating voltage Uc<\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-size:12pt;\">320 V AC<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">test current (8\/20)<sub>In<\/sub><br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;font-size:12pt;\">20 kA<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Max. current (8\/20)<sub>Imax<\/sub><br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;font-size:12pt;\">50 kA<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Voltage protection level Up<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;font-size:12pt;\">\u2264 1.8 kV<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">surge current Iimp<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;font-size:12pt;\">7 kA<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Required protection<\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">32 A<br \/><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Max. connection<\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">35<sup>mm\u00b2<\/sup><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Design<\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">varistor<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Ingress protection class<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">IP20<br \/><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">storage temperature<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">from<span style=\"font-family:verdana, geneva;font-size:12pt;\"><sup>-30\u00b0C<\/sup><\/span> to<sup>+70\u00b0C<\/sup><br \/><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">operating ambient temperature<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">from<sup>-30\u00b0C<\/sup> to<sup>+50\u00b0C<\/sup><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Rail mounting<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">DIN (TH\/TS 35)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Certifications<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">CE, IEC 61643-11<br \/><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">Brand<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;color:#000000;\"><span style=\"font-size:16px;\">Doktorvolt<\/span><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:right;padding:15px;height:25px;\" valign=\"middle\" align=\"right\"><span style=\"font-size:12pt;color:#000000;\"><span style=\"font-family:verdana, geneva;\">catalogue number<br \/><\/span><\/span><\/td>\n<td style=\"background-color:#ffffff;text-align:center;padding:15px;\"><span style=\"font-family:verdana, geneva;font-size:12pt;color:#000000;\">DV-5064<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Surge arrester, surge protector for photovoltaic systems, Class T1\/T2, 4P, 320 V AC, 20\u201350 kA<\/p>\n","protected":false},"featured_media":107915,"template":"","meta":[],"product_brand":[6328],"product_cat":[4980],"product_tag":[],"class_list":["post-110517","product","type-product","status-publish","has-post-thumbnail","product_brand-doktorvolt","product_cat-surge-protective-devices","first","instock","shipping-taxable","product-type-external"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>4P 20\u201350 kA AC T1\/T2 surge arrester, Doktorvolt DV-5064 - DOKTORVOLT\u00ae<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"4P 20\u201350 kA AC T1\/T2 surge arrester, Doktorvolt DV-5064 - DOKTORVOLT\u00ae\" \/>\n<meta property=\"og:description\" content=\"Surge arrester, surge protector for photovoltaic systems, Class T1\/T2, 4P, 320 V AC, 20\u201350 kA\" \/>\n<meta property=\"og:url\" content=\"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/\" \/>\n<meta property=\"og:site_name\" content=\"DOKTORVOLT\u00ae\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-04T09:51:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/doktorvolt.pl\/wp-content\/uploads\/2026\/02\/pol_pl_14475-14475_1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer\\\/modular-apparatus\\\/surge-protective-devices\\\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\\\/\",\"url\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer\\\/modular-apparatus\\\/surge-protective-devices\\\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\\\/\",\"name\":\"4P 20\u201350 kA AC T1\\\/T2 surge arrester, Doktorvolt DV-5064 - DOKTORVOLT\u00ae\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer\\\/modular-apparatus\\\/surge-protective-devices\\\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer\\\/modular-apparatus\\\/surge-protective-devices\\\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/doktorvolt.pl\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/pol_pl_14475-14475_1.jpg\",\"datePublished\":\"2026-02-24T08:17:22+00:00\",\"dateModified\":\"2026-08-04T09:51:03+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer\\\/modular-apparatus\\\/surge-protective-devices\\\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer\\\/modular-apparatus\\\/surge-protective-devices\\\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer\\\/modular-apparatus\\\/surge-protective-devices\\\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\\\/#primaryimage\",\"url\":\"https:\\\/\\\/doktorvolt.pl\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/pol_pl_14475-14475_1.jpg\",\"contentUrl\":\"https:\\\/\\\/doktorvolt.pl\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/pol_pl_14475-14475_1.jpg\",\"width\":1000,\"height\":1000},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer\\\/modular-apparatus\\\/surge-protective-devices\\\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Strona g\u0142\u00f3wna\",\"item\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Offer Doktorvolt\",\"item\":\"https:\\\/\\\/doktorvolt.pl\\\/en\\\/offer-doktorvolt\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"4P 20\u201350 kA AC T1\\\/T2 surge arrester, Doktorvolt DV-5064\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/\",\"name\":\"DOKTORVOLT\u00ae\",\"description\":\"Producent rozdzielnic budowlanych\",\"publisher\":{\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/#organization\",\"name\":\"DOKTORVOLT\u00ae\",\"url\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/doktorvolt.pl\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/DoktorVOLT-black-png.png\",\"contentUrl\":\"https:\\\/\\\/doktorvolt.pl\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/DoktorVOLT-black-png.png\",\"width\":729,\"height\":40,\"caption\":\"DOKTORVOLT\u00ae\"},\"image\":{\"@id\":\"https:\\\/\\\/doktorvolt.pl\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"4P 20\u201350 kA AC T1\/T2 surge arrester, Doktorvolt DV-5064 - DOKTORVOLT\u00ae","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/","og_locale":"en_US","og_type":"article","og_title":"4P 20\u201350 kA AC T1\/T2 surge arrester, Doktorvolt DV-5064 - DOKTORVOLT\u00ae","og_description":"Surge arrester, surge protector for photovoltaic systems, Class T1\/T2, 4P, 320 V AC, 20\u201350 kA","og_url":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/","og_site_name":"DOKTORVOLT\u00ae","article_modified_time":"2026-08-04T09:51:03+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/doktorvolt.pl\/wp-content\/uploads\/2026\/02\/pol_pl_14475-14475_1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/","url":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/","name":"4P 20\u201350 kA AC T1\/T2 surge arrester, Doktorvolt DV-5064 - DOKTORVOLT\u00ae","isPartOf":{"@id":"https:\/\/doktorvolt.pl\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/#primaryimage"},"image":{"@id":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/#primaryimage"},"thumbnailUrl":"https:\/\/doktorvolt.pl\/wp-content\/uploads\/2026\/02\/pol_pl_14475-14475_1.jpg","datePublished":"2026-02-24T08:17:22+00:00","dateModified":"2026-08-04T09:51:03+00:00","breadcrumb":{"@id":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/#primaryimage","url":"https:\/\/doktorvolt.pl\/wp-content\/uploads\/2026\/02\/pol_pl_14475-14475_1.jpg","contentUrl":"https:\/\/doktorvolt.pl\/wp-content\/uploads\/2026\/02\/pol_pl_14475-14475_1.jpg","width":1000,"height":1000},{"@type":"BreadcrumbList","@id":"https:\/\/doktorvolt.pl\/en\/offer\/modular-apparatus\/surge-protective-devices\/ueberspannungsschutz-4p-20-50ka-ac-t1-t2-blitzschutz-doktorvolt-dv-5064\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Strona g\u0142\u00f3wna","item":"https:\/\/doktorvolt.pl\/en\/"},{"@type":"ListItem","position":2,"name":"Offer Doktorvolt","item":"https:\/\/doktorvolt.pl\/en\/offer-doktorvolt\/"},{"@type":"ListItem","position":3,"name":"4P 20\u201350 kA AC T1\/T2 surge arrester, Doktorvolt DV-5064"}]},{"@type":"WebSite","@id":"https:\/\/doktorvolt.pl\/de\/#website","url":"https:\/\/doktorvolt.pl\/de\/","name":"DOKTORVOLT\u00ae","description":"Producent rozdzielnic budowlanych","publisher":{"@id":"https:\/\/doktorvolt.pl\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/doktorvolt.pl\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/doktorvolt.pl\/de\/#organization","name":"DOKTORVOLT\u00ae","url":"https:\/\/doktorvolt.pl\/de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/doktorvolt.pl\/de\/#\/schema\/logo\/image\/","url":"https:\/\/doktorvolt.pl\/wp-content\/uploads\/2023\/10\/DoktorVOLT-black-png.png","contentUrl":"https:\/\/doktorvolt.pl\/wp-content\/uploads\/2023\/10\/DoktorVOLT-black-png.png","width":729,"height":40,"caption":"DOKTORVOLT\u00ae"},"image":{"@id":"https:\/\/doktorvolt.pl\/de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/doktorvolt.pl\/en\/wp-json\/wp\/v2\/product\/110517","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/doktorvolt.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/doktorvolt.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/doktorvolt.pl\/en\/wp-json\/wp\/v2\/media\/107915"}],"wp:attachment":[{"href":"https:\/\/doktorvolt.pl\/en\/wp-json\/wp\/v2\/media?parent=110517"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/doktorvolt.pl\/en\/wp-json\/wp\/v2\/product_brand?post=110517"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/doktorvolt.pl\/en\/wp-json\/wp\/v2\/product_cat?post=110517"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/doktorvolt.pl\/en\/wp-json\/wp\/v2\/product_tag?post=110517"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}