3P C32A 6kA overcurrent circuit breaker with Doktorvolt DV-5002 fuse

3P C32A 6kA overcurrent circuit breaker with fuse, Doktorvolt

MINIATURE CIRCUIT BREAKERS 6kA | DV-5002 | EAN: 5907589335002

Technical specifications

Weight 0,283 kg
Number of poles

3P

Rated current

32A

Doktovolt 3P C32A 6kA circuit breaker

⭐⭐⭐⭐⭐

A circuit breaker is a component of an electrical installation that provides protection against the effects of short circuits and overloads in electrical equipment. Its function is to interrupt the circuit when the current flowing through it exceeds a safe level for that circuit. Overcurrent circuit breakers with a C-type characteristic are characterised by a delayed response. They are used to protect equipment with high inrush currents, such as motors.

Features of the Doktorvolt DV-5002 C32A 6kA 3P overcurrent circuit breaker:

✔️ operating position indicator 

✔️ can be connected using comb-type busbars

✔️ designed for the retrofitting of auxiliary devices

✔️ circuit overload protection

✔️ circuit protection against short circuits

✔️ circuit isolation upon disconnection

✔️ rated current: 32A

✔️ operating characteristics: Type C

✔️ Number of poles (modules): 3

✔️ rated voltage: 400 V

✔️ Rated switching capacity: 6 kA

✔️ DIN rail mounting (TH/TS 35)

Rated current In

32 A

Operating characteristics

C

Number of modules (poles)

3P

Rated voltage Ue

400 V

Operating frequency

50/60 Hz

Rated switching capacity

6 kA

degree of protection

IP20

electrical life (number)

15,000 cycles

Mechanical life (number of cycles)

30,000 cycles
Rail mounting DIN (TH/TS 35)

storage temperature

from -30° to +70°C

operating ambient temperature
(when operating below 0°C, the unit must be protected against frost)

from -30° to +50°C

Maximum terminal capacity

25 mm²

Tightening torque for connection terminals

3 Nm

Installation

internal
dimensions

width: 54 mm

height: 82 mm

depth: 67 mm

operating position indicator

Yes

can be connected using comb rails

yes

Suitable for retrofitting auxiliary devices

yes

circuit overload protection

yes

circuit protection against short circuits

yes

Circuit isolation upon disconnection

yes

Certificates and standards

CE, IEC 60898

Brand

Doktorvolt

manufacturer’s code

DV-5002
EAN code
5907589335002

Doktovolt 3P C32A 6kA circuit breaker

⭐⭐⭐⭐⭐

A circuit breaker is a component of an electrical installation that provides protection against the effects of short circuits and overloads in electrical equipment. Its function is to interrupt the circuit when the current flowing through it exceeds a safe level for that circuit. Overcurrent circuit breakers with a C-type characteristic are characterised by a delayed response. They are used to protect equipment with high inrush currents, such as motors.

Features of the Doktorvolt DV-5002 C32A 6kA 3P overcurrent circuit breaker:

✔️ operating position indicator 

✔️ can be connected using comb-type busbars

✔️ designed for the retrofitting of auxiliary devices

✔️ circuit overload protection

✔️ circuit protection against short circuits

✔️ circuit isolation upon disconnection

✔️ rated current: 32A

✔️ operating characteristics: Type C

✔️ Number of poles (modules): 3

✔️ rated voltage: 400 V

✔️ Rated switching capacity: 6 kA

✔️ DIN rail mounting (TH/TS 35)

Rated current In

32 A

Operating characteristics

C

Number of modules (poles)

3P

Rated voltage Ue

400 V

Operating frequency

50/60 Hz

Rated switching capacity

6 kA

degree of protection

IP20

electrical life (number)

15,000 cycles

Mechanical life (number of cycles)

30,000 cycles
Rail mounting DIN (TH/TS 35)

storage temperature

from -30° to +70°C

operating ambient temperature
(when operating below 0°C, the unit must be protected against frost)

from -30° to +50°C

Maximum terminal capacity

25 mm²

Tightening torque for connection terminals

3 Nm

Installation

internal
dimensions

width: 54 mm

height: 82 mm

depth: 67 mm

operating position indicator

Yes

can be connected using comb rails

yes

Suitable for retrofitting auxiliary devices

yes

circuit overload protection

yes

circuit protection against short circuits

yes

Circuit isolation upon disconnection

yes

Certificates and standards

CE, IEC 60898

Brand

Doktorvolt

manufacturer’s code

DV-5002
EAN code
5907589335002