Doktorvolt DV-5033 2P 25A 30mA Type A residual current device
Doktorvolt 2P 25A 30mA Type A residual current device
RESIDUAL CURRENT CIRCUIT BREAKERS TYPE A | | EAN: 5907589335033
Technical specifications
| Weight | 0,22 kg |
|---|---|
| Number of poles | 2P |
| Residual current | 30mA |
| Rated current | 25A |
Doktorvolt 2P 25A 30mA Type A residual current device
⭐⭐⭐⭐⭐
A residual current device (RCD) is an electrical safety device designed to disconnect the electrical circuit when an imbalance is detected between the incoming and outgoing current.
This solution guarantees protection against electric shock in the event of both indirect and direct contact.
⭐⭐⭐⭐⭐
Features of the Doktorvolt DV-5033 2P 25A 30mA Type A residual current device:
✔️ trip indicator
✔️ can be connected using comb-type busbars
✔️ suitable for the subsequent installation of auxiliary devices
✔️ protection of the system against operational interruptions caused by frequent false tripping
✔️ enhanced reliability in contaminated operating environments
✔️ circuit isolation upon disconnection
✔️ Can be used as a switch for circuits and motors
✔️ rated current: 25 A
✔️ Circuit-breaker type: A
✔️ rated voltage: 230 V
✔️ DIN rail mounting (TH/TS 35)
| Application |
– Disconnects the electrical circuit when an imbalance is detected between the incoming and outgoing current – protection against electric shock in the event of both indirect and direct contact. |
| Type |
A |
| Rated current In | 25A |
| Number of modules |
2 |
| rated voltage Ue | 230 V |
| Operating frequency | 50/60 Hz |
| Rail mounting |
DIN (TH/TS 35) |
| Maximum terminal capacity | 25 mm² |
| tightening torque for connection terminals | 3 Nm |
| Installation | internal |
| dimensions |
width: 35 mm
height: 80 mm
depth: 75 mm
|
| rated residual current | 30 mA |
| Pollution degree | 2 |
| rated switching capacity (short-circuit withstand capacity Inc) | 6 kA |
| Protection rating | IP 20 |
| electrical life | 4,000 cycles |
| Mechanical life | 8,000 cycles |
| Operating ambient temperature (when operating below 0°C, the device must be protected against frost) | from -30 to +70°C |
| storage temperature | from -30 to +70°C |
| trigger indicator | yes |
| Can be connected using comb-type busbars | yes |
| Suitable for retrofitting auxiliary devices | yes |
| system protection against operational interruptions caused by frequent unnecessary tripping |
yes |
| enhanced reliability in contaminated operating environments | yes |
| Circuit isolation upon disconnection | yes |
| can be used as a switch for circuits and motors | yes |
| Certifications |
CE, IEC 61643-11 |
| manufacturer |
Doktorvolt |
| catalogue number |
DV-5033 |
| EAN | 5907589335033 |
Doktorvolt 2P 25A 30mA Type A residual current device
⭐⭐⭐⭐⭐
A residual current device (RCD) is an electrical safety device designed to disconnect the electrical circuit when an imbalance is detected between the incoming and outgoing current.
This solution guarantees protection against electric shock in the event of both indirect and direct contact.
⭐⭐⭐⭐⭐
Features of the Doktorvolt DV-5033 2P 25A 30mA Type A residual current device:
✔️ trip indicator
✔️ can be connected using comb-type busbars
✔️ suitable for the subsequent installation of auxiliary devices
✔️ protection of the system against operational interruptions caused by frequent false tripping
✔️ enhanced reliability in contaminated operating environments
✔️ circuit isolation upon disconnection
✔️ Can be used as a switch for circuits and motors
✔️ rated current: 25 A
✔️ Circuit-breaker type: A
✔️ rated voltage: 230 V
✔️ DIN rail mounting (TH/TS 35)
| Application |
– Disconnects the electrical circuit when an imbalance is detected between the incoming and outgoing current – protection against electric shock in the event of both indirect and direct contact. |
| Type |
A |
| Rated current In | 25A |
| Number of modules |
2 |
| rated voltage Ue | 230 V |
| Operating frequency | 50/60 Hz |
| Rail mounting |
DIN (TH/TS 35) |
| Maximum terminal capacity | 25 mm² |
| tightening torque for connection terminals | 3 Nm |
| Installation | internal |
| dimensions |
width: 35 mm
height: 80 mm
depth: 75 mm
|
| rated residual current | 30 mA |
| Pollution degree | 2 |
| rated switching capacity (short-circuit withstand capacity Inc) | 6 kA |
| Protection rating | IP 20 |
| electrical life | 4,000 cycles |
| Mechanical life | 8,000 cycles |
| Operating ambient temperature (when operating below 0°C, the device must be protected against frost) | from -30 to +70°C |
| storage temperature | from -30 to +70°C |
| trigger indicator | yes |
| Can be connected using comb-type busbars | yes |
| Suitable for retrofitting auxiliary devices | yes |
| system protection against operational interruptions caused by frequent unnecessary tripping |
yes |
| enhanced reliability in contaminated operating environments | yes |
| Circuit isolation upon disconnection | yes |
| can be used as a switch for circuits and motors | yes |
| Certifications |
CE, IEC 61643-11 |
| manufacturer |
Doktorvolt |
| catalogue number |
DV-5033 |
| EAN | 5907589335033 |