
Doktorvolt DV-5040 4P 40A 30mA Type A residual current device
Doktorvolt 4P 40A 30mA Type A residual current device (RCD)
RESIDUAL CURRENT CIRCUIT BREAKERS TYPE A | | EAN: 5907589335040
Technical specifications
| Weight | 0,364 kg |
|---|---|
| Number of poles | 4P |
| Residual current | 30mA |
| Rated current | 40A |
Doktorvolt 5040 4P 40A 30mA Type A residual current device
⭐⭐⭐⭐⭐
A residual current device (RCD) is an electrical safety device designed to disconnect the electrical circuit when an imbalance is detected between the incoming and outgoing current.
This solution ensures protection against electric shock in the event of both indirect and direct contact.
⭐⭐⭐⭐⭐
Features of the Doktorvolt DV-5040 4P 40A 30mA Type A residual current device:
✔️ trip indicator
✔️ can be connected using comb-type busbars
✔️ suitable for the subsequent installation of auxiliary devices
✔️ protection of the system against operational interruptions caused by frequent unnecessary tripping
✔️ enhanced reliability in contaminated operating environments
✔️ circuit isolation upon disconnection
✔️ Can be used as a switch for circuits and motors
✔️ rated current: 40A
✔️ circuit breaker type: A
✔️ Rated voltage: 400 V
✔️ DIN rail mounting (TH/TS 35)
| Application |
– Disconnects the electrical circuit when an imbalance is detected between the incoming and outgoing current – protection against electric shock in the event of both indirect and direct contact. |
| Type |
A |
| Rated current In | 40A |
| Number of modules |
4 |
| rated voltage Ue | 400 V |
| Operating frequency | 50/60 Hz |
| Rail mounting |
DIN (TH/TS 35) |
| Maximum terminal capacity | 25 mm² |
| tightening torque for connection terminals | 3 Nm |
| Installation | internal |
| dimensions |
width: 71 mm
height: 81 mm
depth: 72 mm
|
| rated residual current | 30 mA |
| degree of protection | IP 20 |
| electrical life | 4,000 cycles |
| Mechanical life | 8,000 cycles |
| Operating ambient temperature (when operating below 0°C, the device must be protected against frost) | from -30 to +70°C |
| storage temperature | from -30 to +70°C |
| trigger indicator | yes |
| Can be connected using comb-type busbars | yes |
| Suitable for retrofitting auxiliary devices | yes |
| system protection against operational interruptions caused by frequent unnecessary tripping |
yes |
| enhanced reliability in contaminated operating environments | yes |
| Circuit isolation upon disconnection | yes |
| can be used as a switch for circuits and motors | yes |
| Declarations |
CE, IEC 61008 |
| manufacturer |
Doktorvolt |
| catalogue number |
DV-5040 |
| EAN | 5907589335040 |
Doktorvolt 5040 4P 40A 30mA Type A residual current device
⭐⭐⭐⭐⭐
A residual current device (RCD) is an electrical safety device designed to disconnect the electrical circuit when an imbalance is detected between the incoming and outgoing current.
This solution ensures protection against electric shock in the event of both indirect and direct contact.
⭐⭐⭐⭐⭐
Features of the Doktorvolt DV-5040 4P 40A 30mA Type A residual current device:
✔️ trip indicator
✔️ can be connected using comb-type busbars
✔️ suitable for the subsequent installation of auxiliary devices
✔️ protection of the system against operational interruptions caused by frequent unnecessary tripping
✔️ enhanced reliability in contaminated operating environments
✔️ circuit isolation upon disconnection
✔️ Can be used as a switch for circuits and motors
✔️ rated current: 40A
✔️ circuit breaker type: A
✔️ Rated voltage: 400 V
✔️ DIN rail mounting (TH/TS 35)
| Application |
– Disconnects the electrical circuit when an imbalance is detected between the incoming and outgoing current – protection against electric shock in the event of both indirect and direct contact. |
| Type |
A |
| Rated current In | 40A |
| Number of modules |
4 |
| rated voltage Ue | 400 V |
| Operating frequency | 50/60 Hz |
| Rail mounting |
DIN (TH/TS 35) |
| Maximum terminal capacity | 25 mm² |
| tightening torque for connection terminals | 3 Nm |
| Installation | internal |
| dimensions |
width: 71 mm
height: 81 mm
depth: 72 mm
|
| rated residual current | 30 mA |
| degree of protection | IP 20 |
| electrical life | 4,000 cycles |
| Mechanical life | 8,000 cycles |
| Operating ambient temperature (when operating below 0°C, the device must be protected against frost) | from -30 to +70°C |
| storage temperature | from -30 to +70°C |
| trigger indicator | yes |
| Can be connected using comb-type busbars | yes |
| Suitable for retrofitting auxiliary devices | yes |
| system protection against operational interruptions caused by frequent unnecessary tripping |
yes |
| enhanced reliability in contaminated operating environments | yes |
| Circuit isolation upon disconnection | yes |
| can be used as a switch for circuits and motors | yes |
| Declarations |
CE, IEC 61008 |
| manufacturer |
Doktorvolt |
| catalogue number |
DV-5040 |
| EAN | 5907589335040 |



